Answers are grounded in this paper and cite their sources.
In this paper, a single-phase 10-switch three isolated DC sources (10 V: 20 V: 40 V) based 15-level asymmetric multilevel inverter is presented. A complete analysis of all the 1024 gate combinations verifies all the 15 output levels and 1 switching state for each non-zero level, as well as the full set of forbidden states. Four operating modes (DE-PD, DE-APOD, HHO-PD and HHO-APOD) are simulated with an identical objective, constraints, evaluation budget and 7 quarter -wave switching angles optimized using Differential Evolution (DE) and Harris Hawks Optimization (HHO). The angle sets generated by the two optimizers were very similar (maximum difference of 1.14°). For both PD modes, the voltage THD was 6.957% and the current THD was 0.127%, respectively, while for both APOD modes, these parameters were, respectively, 6.679% and 0.116%. Both modes of the APOD saw a 4.0% and 8.7% reduction in the voltage THD and current THD, respectively, while the choice of optimizer did not measurably affect the simulated output.
No takes yet. Share an insight, caveat, or question.
Laith Hamdi (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: