Answers are grounded in this paper and cite their sources.
Background: Rapid molecular assays are important for improving the timely diagnosis of pulmonary tuberculosis. Truenat and Xpert include several assay variants with diagnostic performance that may vary across populations, testing procedures, and clinical settings. Objective: This systematic review and meta-analysis aimed to summarize the diagnostic accuracy of Truenat and Xpert assays for detecting pulmonary tuberculosis using mycobacterial culture as the reference standard, and to compare the pooled diagnostic performance of Truenat versus Xpert. Materials and methods: PubMed, Scopus, ScienceDirect, SpringerLink, and ProQuest were searched from database inception to 29 September 2026. Eligible studies evaluated at least one Truenat assay and one Xpert assay within the same participant cohort or paired specimen set and provided sufficient data to construct separate 2×2 contingency tables against mycobacterial culture. Pooled sensitivity and specificity with 95% confidence intervals (CIs) were estimated using bivariate random-effects models. Assay-variant subgroup analyses were conducted, and methodological quality was assessed using an adapted QUADAS-2 framework. Results: Thirteen studies comprising 14 independent cohorts were included. The primary analyses included 14 Truenat and 14 Xpert datasets. Truenat had a pooled sensitivity of 0.87 (95% CI, 0.83–0.90) and specificity of 0.94 (95% CI, 0.89-0.97), with a bivariate I² of 64.2%. Xpert had a pooled sensitivity of 0.92 (95% CI, 0.88-0.95) and specificity of 0.97 (95% CI, 0.93-0.99), with a bivariate I² of 74.1%. Subgroup estimates were broadly similar across the variants within each platform. Risk-of-bias concerns were most frequent in the flow and timing domain. No formal statistical comparison was performed between the two platforms. Conclusion: Both Truenat and Xpert demonstrated high pooled diagnostic accuracy for pulmonary tuberculosis. Xpert produced numerically higher pooled sensitivity and specificity, but the separate platform-specific analyses did not establish its superiority over Truenat. The heterogeneity observed in both analyses indicates that assay performance may vary across study populations and testing conditions. Platform selection should therefore consider diagnostic accuracy together with operational feasibility, infrastructure requirements, and the intended testing setting.
No takes yet. Share an insight, caveat, or question.
Afandi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: