Answers are grounded in this paper and cite their sources.
High-rate discharge increases battery thermal loads, while longer coolant paths and stronger local disturbances can raise the hydraulic cost of cooling. A stepped-flow racetrack-rib cold plate is proposed for a 50 Ah prismatic LiFePO 4 cell. Local ribs enhance coolant transport near the tab-side hot region, and connected downstream passages sustain cooling over the remaining surface. A three-dimensional NTGK conjugate-heat-transfer model is validated against cell-temperature measurements and published pressure-drop data. Single-factor variations and 30 combined computational fluid dynamics designs are assessed using thermal–hydraulic indicators, system performance index, and three-criterion TOPSIS. The cold plate reduces maximum temperature by 7.65%, 11.14%, and 11.73% at 1C, 2C, and 3C, respectively, including a 4.63 °C reduction at 3C. The preferred representative configuration lowers pumping power by 5.48% and raises the cooling-efficiency coefficient by 8.95% relative to the high-pumping comparison case. Flow analysis links this performance to repeated splitting, redirection, and sustained downstream delivery, supporting high-rate cooling with low hydraulic demand.
No takes yet. Share an insight, caveat, or question.
Lan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: