Answers are grounded in this paper and cite their sources.
Optical lenses, especially eyeglass lenses that have been in use for some time, commonly exhibit scratch defects on their surfaces. To address the challenge of weak defect signal extraction, we propose a defect enhancement method based on the light intensity peak-to-peak (Ipp) feature within a phase-shifting schlieren imaging system. Conventional phase-shifting schlieren methods often rely on phase retrieval and phase unwrapping, in which weak defect signals are easily overwhelmed by background noise. The proposed method uses the pixel-wise intensity variation amplitude (Ipp) over 28 phase-shifting steps to generate a new image, achieving defect signal enhancement over a field of view of about 33 mm×28 mm. Across 110 in-service defect samples, all defects are consistently enhanced, achieving a mean contrast-to-noise ratio enhancement ratio of 374% with a median of 256%. The proposed method achieves a favorable balance among sensitivity, robustness, and efficiency, while retaining the large field-of-view advantage of schlieren imaging, providing a practical and scalable solution for optical defect inspection.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: