Textile-mediated smartphone phonocardiography (PCG) depends strongly on the mechanical interface between the body, clothing, coupling layer, and smartphone microphone. This study examined whether increasing the static mechanical compliance of a silicone coupling layer produces a corresponding improvement in PCG recording quality. Two-dimensional static plane-stress finite-element analysis (FEM) quantified relative compliance for idealized continuous silicone layers of 1, 2, and 3 mm. Relative loaded-surface displacement increased from 1.000 to 2.042 and 3.127, respectively. Experimentally, three independently repositioned recordings were obtained for four conditions under a two-layer cotton interface: no silicone, one 1-mm layer, two stacked 1-mm layers, and three stacked 1-mm layers. Recording-level envelope signal-to-noise ratio (EnvSNR) was 5.64 ± 1.01 dB without silicone and 23.48 ± 1.85, 22.13 ± 1.42, and 21.86 ± 1.69 dB for the one-, two-, and three-layer conditions. Leave-one-replicate-set-out model comparison showed lowest prediction error for silicone-presence/plateau and rapidly saturating FEM-informed models (RMSE 1.56 dB), whereas linear layer-count and linear FEM-compliance models performed worse (RMSE 5.29 and 5.38 dB). Thus, static compliance increased monotonically, but recording quality did not improve proportionally after silicone introduction.