Specimen transport is widely promoted as the binding constraint on diagnostic turnaround time in district hospital laboratories, yet the causal claim that reconfiguring transport shortens the interval from specimen collection to treatment initiation is rarely separated from the laboratory-internal and clinical-decision components of that interval. It decomposes total diagnostic delay into transport, analytical, reporting and clinical-initiation segments; shows that a transport intervention can only shift the segments it touches; and demonstrates that a level-and-slope segmented regression on a single interrupted series identifies the transport-attributable effect only under stated assumptions about the counterfactual trend, seasonality, co-interventions and the composition of test mix. The central proposition is that transport interventions produce their largest proportional gains on the transport segment and on high-volume, low-complexity tests, and that measured reductions in total turnaround time will be smaller than the transport saving unless reporting and clinical-initiation delays are addressed concurrently. The article specifies the estimator, the falsification conditions and the boundary conditions under which the inference stops holding, and argues that evaluations reporting only mean total turnaround time overstate transport effects while understating the clinical-initiation bottleneck.
No takes yet. Share an insight, caveat, or question.
Kaggwa et al. (2026) studied this question.