The horse-head wall (firewall) is the most iconic structural element of Hui‑style architecture in China. Under the combined effects of sidewall height and burner-to-sidewall distance, the fire behavior on a pitched roof under crosswind conditions becomes highly complex. In this study, a series of experiments was conducted at a crosswind speed of 1.50 m/s and a fixed slope angle of 30°. The sidewall heights were 0.20 m, 0.30 m, and 0.40 m, and burner-to-sidewall distances were 0.10 m, 0.20 m, 0.30 m, and 0.40 m. The flame morphology (flame height, horizontal flame length), flow field, and temperature field were measured and analyzed. The experimental results indicate that as the burner-to-sidewall distance increases, the flame morphology gradually transitions from a confined state attached to the sidewall to a deflected flame. The flame height increases with increasing sidewall height and decreases with increasing burner-to-sidewall distances. Based on a physical model and dimensionless analysis, a prediction model for flame height is established under crosswind conditions, accounting for the combined effects of sidewall height and burner-to-sidewall distance.