Animal welfare motivated this planning-level assessment of elevated photovoltaic (PV) canopies and four vertical-axis wind turbines (VAWTs) for a nominal 400.00 m 2 feedlot pen near Lethbridge, Alberta. The structure was intended to support shade, renewable electricity and precision-monitoring equipment. The quantitative case used 20.00 ft × 50.00 ft and 10.00 ft × 31.00 ft canopy plans, with calculated shade and reduced-order airflow indicators. The canopies had a combined plan area of 121.70 m 2 , or 30.43% of the reference pen area. The capped gross projected-shade area index averaged 31.18% over June–August at solar-hour indices 08:00–17:00 and 32.94% at indices 09:00, 15:00 and 17:00. These indices excluded shadow overlap and clipping to pen or bedding boundaries. The annual hybrid scenario total was 7.58 MW h, combining calculated PV output with a prescribed 0.94 MW h wind contribution. With an installed-cost allowance of CAD $75,500 and an assumed annual shade benefit of CAD $6000, the 25-year appraisal yielded NPV of CAD $907, IRR of 6.03% and simple payback of 12 years. The concept therefore shows that a feedlot can treat renewable-energy infrastructure as a multifunctional asset, improving thermal comfort for the animals, supporting precision livestock monitoring and producing electricity from the same structure.