Answers are grounded in this paper and cite their sources.
Leakage from buried water pipelines causes water loss and can lead to road collapse. Ground-penetrating radar (GPR) is sensitive to changes in soil permittivity caused by leakage. However, strong pipe reflections and noise make it difficult to pinpoint the leak. Numerical simulations and laboratory experiments show that leakage produces a reflection from the wetting front and delays the arrival of the pipe reflection in GPR B-scans. These features indicate leakage but give limited information about its exact location. In C-scans, the spread of water into the surrounding soil produces an approximately circular wetting front reflection and an intersection with the pipe-related anomaly. We use a modified second-generation coherence algorithm (C2) to highlight the leakage-related anomaly in the C-scan slices, and then apply a circular Hough transform to fit the wetting-front reflection and estimate the center of the wetted zone. We combine the highlighted anomaly with the estimated center of the wetted zone to locate the leak in both simulated and laboratory data.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: