Answers are grounded in this paper and cite their sources.
Open-end-winding permanent magnet synchronous motors have benefits such as a lower phase current and smaller motor size, which are made possible by the incorporation of dual inverters for better use of the available voltage. However, these systems can generate a zero-sequence current (ZSC) because of the harmonic back EMF and common-mode voltage, which increases power loss and causes torque ripple. The available zero-sequence voltage (ZSV) range depends on the switching sector. This paper presents a dual-inverter space vector pulse width modulation method that selects inverter clamping transitions online according to the analytically derived ZSV range. Experimental results obtained at four operating points with a peak phase-current magnitude of 30 A and different motor speeds and phase-current angles show that the proposed method reduces the normalized zero-sequence current distortion by an average of 7.49 percentage points compared with the conventional fixed-angle method.
No takes yet. Share an insight, caveat, or question.
Jin et al. (2026) studied this question.