Answers are grounded in this paper and cite their sources.
Microbially influenced corrosion (MIC) of carbon steel was investigated for 6 months at 30°C under anoxic conditions of the French high‐level radioactive waste disposal concept, in Callovo‐Oxfordian pore water and claystone, without and with three cement grouts of increasing alkalinity. Inoculated, nutrient‐fed biotic conditions were compared with non‐sterile ones, whose only microflora came from the claystone. Corrosion was followed with coupons and electrical resistance probes, and bacterial populations by culture‐based counts, qPCR and 16S rRNA sequencing. Supernate pH spanned 8.2–12.1. MIC (> 100 µm localized depth) developed without grout and in the supernate of the least alkaline grout: average corrosion 5.5–14.4 µm, localized 147–381 µm, against ≤ 2.1 and ≤ 15.7 µm when non‐sterile, where shallower attack also developed. In one cement grout 2 supernate whose pH fell to 7.3, a sulfidogenic community settled below that level. Coupons buried in grout showed no MIC (≤ 0.9 and ≤ 4.2 µm); above pH ≈11, MIC‐related groups stayed at detection limits. At higher temperatures, the alkalinity maintained in the supernate and the grout barrier controlled MIC.
No takes yet. Share an insight, caveat, or question.
Diler et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: