Traditional skywell courtyard dwellings are valuable climate responsive heritage, yet the relative influence of geometric and envelope parameters on free running thermal comfort remains insufficiently quantified for conservation oriented design. This study investigates two representative dwellings, H46 and H34, using seasonal field measurements and field calibrated Rhino, Grasshopper, and EnergyPlus simulations. Thermal comfort is assessed using the adaptive Predicted Mean Vote method specified in GB/T 50,785-2012, and a combined summer winter comfort hour ratio is calculated for the representative main hall. Global sensitivity analysis uses 200 Latin Hypercube Sampling cases generated in SimLab, with PRCC and SRCC applied to evaluate parameter importance. Model calibration shows CV(RMSE) values of 12.1–12.3% in summer and 6.13–7.30% in winter. H46 shows weak and statistically non significant PRCC results, whereas H34 shows significant sensitivity to roof related and selected skywell and wall parameters. The marked PRCC and SRCC divergence for H46 indicates that roof insulation material and thickness should be interpreted as a coupled performance package. Skywell geometry is therefore treated as diagnostic heritage information rather than direct retrofit guidance. The findings support low intervention thermal improvement by distinguishing sensitivity evidence from conservation compatible actions for historic skywell dwelling conservation practice.
No takes yet. Share an insight, caveat, or question.
Tian et al. (2026) studied this question.