Why the study?
The limited availability of comprehensive mechanical property data for native human aortic valve leaflets constrains the development of accurate finite element models and age-adapted prosthetic materials.
Comparison
Associations of donor age, body weight, sex, CHD, and HTN with uniaxial tensile properties
Design
Ex vivo biomechanical testing within 24 h postmortem
Answers are grounded in this paper and cite their sources.
Shows donor age correlates with reduced failure strain and strain energy density in human aortic valve leaflets, highlighting parameters for age-adapted prosthetic valve design.
Background: The limited availability of comprehensive mechanical property data for native human aortic valve leaflets constrains the development of accurate finite element models and age-adapted prosthetic materials. This study aimed to characterize the uniaxial tensile behavior of human aortic valve cusps in the radial direction and to evaluate the influence of donor age, body weight, sex, coronary heart disease (CHD), and hypertension (HTN) on these properties. Methods: Fifty leaflet samples from 20 human donors were obtained from human cadavers of varying age, weight, and cardiovascular history, and tested within 24 h postmortem under physiological conditions (38 °C, 0.9% saline) at a displacement speed of 60 mm/min. Force–displacement data were converted to stress–strain curves, from which ultimate tensile strength, maximum strain, elastic moduli of the toe and linear regions, and strain energy were derived. Results: Nonlinear S-shaped curves with distinct toe and linear regions were observed in all samples. Mean values were as follows: ultimate tensile strength 2.41 MPa, failure strain 0.195, toe- and linear-region moduli 11.01 and 14.83 MPa, and strain energy density 0.209 MJ/m3. In linear mixed-effects models with donor as a random intercept, age was associated with failure strain (−1.9% per year, 95% CI −3.1 to −0.7; p = 0.003) and, more weakly, with strain energy density (−2.7% per year, 95% CI −4.8 to −0.6; p = 0.012), whereas no association was found with strength. Body weight was not associated with any parameter after accounting for clustering within donors (p ≥ 0.34). Conclusions: Donor age was associated with reduced failure strain and strain energy density without a detectable change in ultimate tensile strength. These data provide age-stratified reference values for validating constitutive models and for designing age-specific bioprosthetic and tissue-engineered heart valves.
No takes yet. Share an insight, caveat, or question.
Tsilibin et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: