Key result
Paired sinus and PVC deep learning improves ventricular ectopic localization by ~3 points over PVC-only ECGs.
Why the study?
Most AI-based ECG models localize PVCs before catheter ablation without incorporating patient-specific baseline ventricular conduction patterns, and the incremental value of adding paired sinus rhythm recordings to PVC-only input needed evaluation.
Does a QRS-centered deep learning framework integrating paired sinus rhythm and PVC 12-lead ECG recordings improve binary LV versus RV ectopic origin localization compared to PVC-only ECG input in patients undergoing catheter ablation for PVCs?
Observational (n=270)
No
Does a QRS-centered deep learning framework integrating paired sinus rhythm and PVC 12-lead ECG recordings improve binary LV versus RV ectopic origin localization compared to PVC-only ECG input in patients undergoing catheter ablation for PVCs?
Incorporating patient-specific baseline sinus rhythm ECG waveforms alongside PVC morphology in a deep learning model significantly improves non-invasive binary discrimination between left and right ventricular PVC origins compared to analyzing PVC waveforms alone.
Answers are grounded in this paper and cite their sources.
Paired ECG DL input may enhance ectopic localization accuracy; extends PVC-only models but remains hypothesis-generating pending prospective validation.
BACKGROUND: Accurate non-invasive localization of premature ventricular contractions (PVCs) is important for preprocedural planning before catheter ablation. Most artificial intelligence-based electrocardiography (ECG) models evaluate ectopic beats without incorporating patient-specific baseline ventricular conduction patterns. This study aimed to develop and evaluate a patient-referenced, QRS-centered deep learning framework integrating paired sinus rhythm and PVC 12-lead ECG recordings for binary localization of ventricular ectopic origin and to assess the incremental value of sinus rhythm information compared with PVC-only input. METHODS: This retrospective, single-center diagnostic accuracy study included 270 patients with paired sinus rhythm and PVC ECG recordings and procedurally confirmed ventricular ectopic origin. Raw ECG signals were segmented using annotated QRS boundaries and aligned using a QRS-centered strategy. Three input strategies were evaluated: paired PVC + sinus rhythm, PVC-only, and sinus rhythm-only. A 1-dimensional residual convolutional neural network (CNN) (1D ResNet) and a 2-dimensional time-domain CNN (2D time-domain CNN) were trained directly on raw ECG waveforms, with late-fusion probability averaging used for ensemble predictions. Performance was assessed using 5-fold patient-level cross-validation. The primary endpoint was the area under the receiver operating characteristic curve (AUROC). RESULTS: For paired PVC + sinus rhythm input, pooled AUROC values were 0.753 for the 1D ResNet, 0.743 for the 2D time-domain CNN, and 0.762 for the late-fusion ensemble, with no statistically significant differences among architectures. In the cross-input comparison, ensemble AUROC was 0.762 for paired PVC + sinus rhythm, 0.731 for PVC-only, and 0.551 for sinus rhythm-only input. Paired PVC + sinus rhythm significantly outperformed PVC-only input (DeLong P = .0313), whereas sinus rhythm alone showed limited discrimination. CONCLUSION: Patient-specific sinus rhythm information provided incremental discriminatory value when combined with PVC morphology for binary left ventricular-right ventricular (LV-RV) localization, while sinus rhythm alone had limited discriminatory value. These findings provide proof-of-concept evidence supporting paired sinus rhythm-PVC modeling as a physiologically informed approach to ventricular ectopic localization. External validation and comparison with established ECG-based localization criteria are required before clinical implementation.
No takes yet. Share an insight, caveat, or question.
Şipal et al. (2026) conducted an observational in Premature ventricular contractions (PVCs) (n=270). Paired PVC and sinus rhythm 12-lead ECG deep learning framework (late-fusion ensemble of 1D ResNet and 2D time-domain CNN) vs. PVC-only 12-lead ECG deep learning input was evaluated on Area under the receiver operating characteristic curve (AUROC) for binary left ventricular versus right ventricular ectopic origin localization (p=0.0313). Paired sinus rhythm and PVC ECG deep learning improved binary ventricular ectopic origin localization compared to PVC-only input.
Synapse has enriched 10 related papers. Consider them for comparative context: