Key result
Advanced CMR adoption varies widely across centers, with AI predominantly applied for post-processing in ~86%.
Why the study?
The implementation of advanced CMR technologies and institutional readiness for multicenter research remain incompletely characterized.
Cross-Sectional (n=83)
Yes
This international survey reveals substantial heterogeneity in the adoption of advanced CMR techniques, AI integration, complex CIED scanning practices, and administrative timelines for data sharing, highlighting key infrastructural barriers to multicenter CMR research.
Answers are grounded in this paper and cite their sources.
Widespread real-time cine use during arrhythmias at surveyed CMR sites; leaves open standardization and multicenter research readiness.
Background: Advanced cardiovascular magnetic resonance (CMR) technologies offer opportunities for myocardial characterization, arrhythmia assessment, artificial intelligence (AI), and image-guided management, but their implementation and institutional readiness for multicenter research remain incompletely characterized. Objectives: To assess advanced CMR utilization, AI and electrophysiology applications, MRI practices for patients with cardiac implantable electronic devices (CIEDs), and multicenter research readiness. Methods: An electronic survey was distributed to approximately 2000 Society for Cardiovascular Magnetic Resonance members with available contact information. Questions addressed advanced imaging, AI, CIED MRI, electrophysiology, sequence sharing, data de-identification, and administrative approval timelines. Results: Eighty-three respondents from 80 institutions across 23 countries and five continents completed the survey. Respondents were based in North America (44.6%), Europe (30.1%), Asia (22.9%), South America (1.2%), and Oceania (1.2%). Utilization varied for real-time cine imaging during arrhythmias (79.5%), phase-sensitive inversion recovery with motion correction (73.5%), 4D flow (59.0%), wideband late gadolinium enhancement (55.4%), diffusion tensor imaging (19.3%), and MR fingerprinting (7.2%). AI was used predominantly for post-processing (85.5%) and reconstruction (54.2%), compared with clinical decision support and risk prediction (13.3% each). Routine MRI scanning with epicardial, abandoned, and retained leads was reported by 39.8%, 38.6%, and 27.7%, respectively. Although 84.3% could share or receive research pulse sequences, data-sharing agreements required less than two months at 28.9% of sites, three to six months at 36.1%, and more than six months at 20.5%. Conclusions: Advanced CMR adoption, AI integration, CIED MRI practices, and research infrastructure varied substantially among surveyed institutions. Because respondents may represent centers more engaged in advanced CMR, barriers in the broader community may be greater. Technical standardization, training, infrastructure investment, and streamlined approvals could facilitate multicenter research.
No takes yet. Share an insight, caveat, or question.
Bilchick et al. (2026) reported a cross-sectional. Advanced cardiovascular magnetic resonance capabilities, AI integration, and CIED MRI practices was evaluated on Utilization of advanced CMR, AI, CIED MRI practices, and multicenter research readiness. Advanced CMR utilization ranged from 79.5% for real-time cine imaging to 7.2% for MR fingerprinting, while AI was mostly used for post-processing across 80 institutions.