Key result
Early neonatal echocardiography detects significant congenital heart disease in ~6% of newborns.
Why the study?
The burden of undetected CHD in India is large, yet hospital-based echocardiographic prevalence data from South India remain sparse.
What is the birth prevalence and echocardiographic pattern of congenital heart disease, and what is the diagnostic accuracy of CCHD pulse oximetry screening against echocardiography in neonates born at a tertiary care hospital in South India within 72 hours of life?
Cross-Sectional (n=507)
The echocardiographer was blinded to the results of the initial clinical evaluation
No
What is the birth prevalence and echocardiographic pattern of congenital heart disease, and what is the diagnostic accuracy of CCHD pulse oximetry screening against echocardiography in neonates born at a tertiary care hospital in South India within 72 hours of life?
Answers are grounded in this paper and cite their sources.
Universal newborn screening within 72 hours of birth at a South Indian tertiary hospital revealed a high significant CHD prevalence of 57.2/1000 live births (predominantly PDA >2mm and VSD) and validated the high sensitivity (96.6%) and negative predictive value (99.8%) of CCHD pulse oximetry screening against echocardiography.
Background: Congenital heart disease (CHD) is the most common structural congenital anomaly and a leading cause of infant mortality. In India, with over 25 million annual live births, the burden of undetected CHD is enormous. Hospital-based echocardiographic prevalence data from South India, particularly coastal Karnataka, remains sparse. The aim is to assess the birth prevalence and echocardiographic pattern of congenital heart disease in neonates born at a tertiary care hospital within 72 hours of life. Methods: A hospital-based cross-sectional observational study was conducted over six months at Rajarajeswari Medical College and Hospital, Bengaluru. All 507 enrolled neonates underwent CCHD screening followed by transthoracic two-dimensional echocardiography with colour Doppler by a pediatric cardiologist. CHD was classified as normal, insignificant, significant (minor/major acyanotic/cyanotic), or other cardiac findings. Prevalence was expressed per 1000 live births with 95% confidence intervals using the Wilson Score Method. Association of risk factors with CHD was assessed by Fisher's Exact Test (p<0.05). Results: Of 507 neonates screened, 29 (5.72%) had significant CHD, yielding a hospital-based prevalence of 57.2/1000 (95% CI: 40.12–80.94). PDA >2mm was the most frequent diagnosis (n=9, 31.0%), followed by restrictive VSD (n=8, 27.6%) and ASD >5mm (n=7, 24.1%). Five major CHDs were detected: 2 acyanotic (non-restrictive VSD) and 3 cyanotic (DORV, TOF, Ebstein's anomaly). PPHN was identified in 3 neonates. The CCHD screen demonstrated a sensitivity of 96.6% (95% CI: 82.8–99.4%), specificity of 98.7%, and NPV of 99.8%. Preterm gestational age was the only variable significantly associated with CHD (p=0.046). Conclusions: In this hospital-based cross-sectional study of 507 neonates screened by echocardiography within 72 hours of birth, the birth prevalence of significant CHD was 57.2/1000, with PDA being the most common diagnosis. The CCHD screen demonstrated a high sensitivity of 96.6% and NPV of 99.8% when validated against echocardiography.
No takes yet. Share an insight, caveat, or question.
Maguluri et al. (2026) conducted a cross-sectional in Congenital heart disease (CHD) (n=507). Critical Congenital Heart Disease (CCHD) pulse oximetry screening and transthoracic two-dimensional echocardiography with colour Doppler was evaluated on Birth prevalence of significant congenital heart disease per 1000 live births (95% CI 40.12-80.94). Transthoracic echocardiography within 72 hours of life detected significant congenital heart disease in 5.72% of neonates.
Synapse has enriched 10 related papers. Consider them for comparative context: