Key result
Redo-MVR in a fragile annulus causes iatrogenic aortic cusp perforation requiring emergency valve replacement.
Why the study?
Iatrogenic aortic regurgitation is a recognized but likely under-reported complication of MVR, and redo-MVR may heighten this risk when prosthesis explantation leaves a weakened annulus requiring deeper suture bites.
Case Report (n=1)
No
During redo-mitral valve replacement in a weakened annulus, deep suture bites can entrap and perforate the aortic valve cusps, a complication that may be masked by deliberate postoperative hypotension and requires routine post-bypass TEE evaluation of the aortic valve.
Answers are grounded in this paper and cite their sources.
Heightened vigilance for iatrogenic AR is warranted in redo-MVR; this case leaves open optimal preventive strategies.
Background Iatrogenic aortic regurgitation is a well-recognized but probably under-reported complication of mitral valve replacement (MVR). Redo-MVR may increase this risk, because explantation of a long-standing prosthesis can leave an attenuated annulus that requires deeper suture bites. We report such a case to highlight practical lessons for prevention and detection rather than a novel mechanism. Case presentation An 80-year-old woman underwent redo-MVR for severe mitral stenosis 9 years after bioprosthetic MVR. After explantation and debridement, the mitral annulus was markedly fragile, and some sutures may have been placed deeper than usual to secure the prosthesis. Post-bypass transesophageal echocardiography (TEE) focused on the mitral prosthesis and showed no paravalvular leak; the aortic valve was not evaluated in detail. Blood pressure was intentionally kept low after surgery to avoid left ventricular rupture. On postoperative day 1, when blood pressure was raised in preparation for extubation, a wide pulse pressure became apparent, and TEE revealed severe aortic regurgitation with restricted motion of the left coronary cusp. At emergency reoperation, a mitral annular suture had entrapped the attachment of the left coronary cusp, causing marked distortion and a 5-mm perforation. Aortic valve replacement was performed, and the patient was discharged after an uneventful recovery. Conclusions When the mitral annulus is weakened after prosthesis explantation, surgeons should recognize that aortic cusp entrapment can occur despite awareness of this risk, favor annular reinforcement over deeper bites, and verify aortic valve competence before closure. Post-bypass TEE should include the aortic valve, and deliberate postoperative hypotension after MVR may mask iatrogenic aortic regurgitation until blood pressure is raised.
No takes yet. Share an insight, caveat, or question.
Yokoyama et al. (2026) conducted a case report in Iatrogenic aortic valve injury and severe aortic regurgitation after redo-mitral valve replacement (n=1). Redo-mitral valve replacement and emergency aortic valve replacement was evaluated on Iatrogenic aortic regurgitation and cusp perforation requiring emergency reoperation. Redo-mitral valve replacement in a fragile annulus caused a 5-mm left coronary cusp perforation and severe aortic regurgitation detected on postoperative day 1, requiring aortic valve replacement.
Synapse has enriched 10 related papers. Consider them for comparative context: