Key result
EVAR plus false-lumen shape-memory polymer embolization shrinks dissected AAA diameter by ~4 mm at 6 months.
Why the study?
EVAR for abdominal aortic aneurysms with type B aortic dissection is challenging, and conventional embolization poses a risk of rupture due to aortic fragility.
Does EVAR combined with extensive false-lumen embolization using a shape-memory polymer promote sac regression and abolish leaks in a patient with a TBAD-associated AAA requiring strict anticoagulation?
Case Report (n=1)
Does EVAR combined with extensive false-lumen embolization using a shape-memory polymer promote sac regression and abolish leaks in a patient with a TBAD-associated AAA requiring strict anticoagulation?
Parallel deployment of EVAR and extensive false-lumen embolization using a shape-memory polymer achieved sac regression (58 mm to 54 mm) and leak abolition at 6 months in a patient with a dissected AAA on strict anticoagulation.
Answers are grounded in this paper and cite their sources.
May allow safe false-lumen embolization in fragile aortas; leaves open efficacy and requires prospective validation.
Endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAAs) with type B aortic dissection (TBAD) is challenging. We treated a 75-year-old man with a 58-mm TBAD-associated AAA requiring strict anticoagulation after Bentall procedure, using EVAR and extensive false lumen embolization with a novel shape-memory polymer. Conventional embolization poses a risk of rupture due to aortic fragility. Polymer pressure attenuation and secondary thrombosis promoted successful sac regression. At six months, the AAA regressed to 54 mm, and the leak was abolished. This parallel deployment technique offers a safe, rapid, and effective alternative for anatomically complex off-label aortic pathologies requiring strict anticoagulation.
No takes yet. Share an insight, caveat, or question.
Sakurai et al. (2026) conducted a case report in 58-mm type B aortic dissection-associated abdominal aortic aneurysm requiring strict anticoagulation after Bentall procedure (n=1). Endovascular aneurysm repair (EVAR) with extensive false-lumen embolization using a novel large-diameter shape-memory polymer was evaluated on Aneurysm sac regression and abolition of leak at 6 months. EVAR with extensive false-lumen shape-memory polymer embolization reduced the dissected abdominal aortic aneurysm diameter from 58 mm to 54 mm and abolished the leak at 6 months.
Synapse has enriched 10 related papers. Consider them for comparative context: