Composite structures manufactured via Automated Fibre Placement (AFP) are commonly qualified using coupon-scale mechanical tests, under the assumption that this data represents larger-scale structural behaviour. This study examines whether such results can be carried upward in a building-block certification approach. To investigate this claim, aligned and staggered gap configurations were tested under tension across two specimen sizes. Strength, stiffness, damage initiation, and edge delamination were evaluated experimentally, supported by numerical modelling of the defects to examine stress distributions and free-edge effects. Staggered gaps showed consistent strength and edge delamination behaviour regardless of specimen size, whereas aligned gaps were size-dependent. This was attributed to the complex stress state introduced by the through-thickness arrangement of the gaps. Aligned gaps also promoted local bonding between adjacent 0° plies, which arrested delamination growth and introduced a scaling effect on strength. Coupon-scale representativeness therefore depends on the degree to which defects interact, either with one another or with surrounding plies. Coupon strength results can be carried up the test pyramid for staggered gaps separated by at least one tow width and located in different plies. Where defects align through the thickness, characterisation at element level is required.