Answers are grounded in this paper and cite their sources.
We propose an all-quartz fiber Fabry-Pérot high-temperature acoustic pressure sensor based on micro-electro-mechanical system (MEMS) technology. We investigate the signal-to-noise ratio (SNR) enhancement from the synergistic structure of a fiber-optic microsphere lens and a nanocone forest array, with sensing performance validated at 800 °C. The composite structure raises the interference spectral SNR by 23.2 dB. Fabricated via wafer-level all-quartz processes and adhesive-free laser fusion splicing, the sensor reaches a sensitivity of 0.067 nm/Pa from 118.586 to 169.624 dB acoustic pressure at room temperature, with low nonlinearity (0.81% F.S.), repeatability error (0.28% F.S.) and minor cavity-length drift. It maintains good thermal stability at 800 °C without nanocone array failure. This batch-fabricable, electromagnetic-interference-immune sensor offers a new strategy for signal optimization of multilayer Fabry-Pérot structures for aerospace high-temperature acoustic tests.
No takes yet. Share an insight, caveat, or question.
wang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: