Answers are grounded in this paper and cite their sources.
Photovoltaic- thermal (PV-T) systems integrate electricity generation and heat recovery through thermal management of photovoltaic modules. This study experimentally evaluates the coupled electrical and thermal performance of a rear copper-coiled heat exchanger-integrated thermosyphon PV-T system operating at a low natural-circulation flow rate under semi-arid outdoor conditions in Kobo, Ethiopia. A 100 W PV module fitted with a copper coil heat exchanger was tested simultaneously with a stand-alone PV module over three days in June. Water circulated naturally at approximately 0.004 kg/s without a mechanical pump. The assessment combines module temperature measurements, electrical comparison with the PV reference, and useful heat recovery under the same environmental conditions. Around 11:00, the PV-T front surface temperature was 13 ℃ lower than that of the reference module. Average electrical efficiency reached 16.74%, compared with 10.5% for standalone PV, an increase of 6.24 percentage points. The maximum outlet water temperature was 52.88 ℃ , while average thermal and combined efficiencies were 41.7% and 58.44%, respectively. These findings revealed that the rear copper coil thermosyphon PV-T system improved electrical performance relative to stand-alone PV while recovering useful heat for water heating. The results support low-flow natural circulation as an effective approach to combined solar electricity generation and water heating under the tested semi-arid conditions.
No takes yet. Share an insight, caveat, or question.
Asnake et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: