Powder catchment efficiency (PCE) is a critical parameter influencing both feedstock utilization and geometric fidelity in powder-blown laser directed energy deposition. Conventionally, PCE is determined gravimetrically, by weighing the finished part after removal from the substrate. This yields only a single build-averaged value and does not capture variations in PCE during deposition. This study introduces coaxial inline coherent imaging (ICI) as an in-situ, non-destructive route to measuring PCE. A low-coherence imaging beam, aligned with the process optics, interrogates the solidified surface behind the melt pool. The resulting height field is referenced to the substrate and integrated to obtain the deposited volume, from which PCE is calculated without weighing. The method was evaluated on Ti-6Al-4V single-track thin walls across a 54-condition process window. For the 50 specimens with valid gravimetric pairs, the root-mean-square difference between the two methods was 3.4 percentage points, with the optical estimate reading 0.6 points higher than the balance on average and 95 % of specimens falling within ±6.6 points of the gravimetric value. Because the surface is measured after every deposited layer, PCE was also calculated layer by layer. This reveals that efficiency is not constant: it rises over the first few layers, then declines steadily with build height, a drift that build-averaged weighing conceals. Across the process window, powder feed rate emerged as the dominant factor controlling catchment.