Answers are grounded in this paper and cite their sources.
Background/Objectives: To evaluate the color agreement of a digital single-lens reflex (DSLR) camera and three smartphone systems (iPhone 17 Pro Max, Google Pixel 10 Pro, Samsung Galaxy S26 Ultra) against a reference spectrophotometer for tooth shade matching, and to conduct an exploratory analysis of AI-based color correction and uncertainty flagging. Methods: The study comprised a laboratory phase using 29 VITA 3D-Master shade tabs and a clinical phase involving maxillary central incisors of 100 participants. Images were captured under standardized LED illumination and calibrated using a neutral gray reference. Euclidean color differences (ΔEab*) were calculated against a VITA Easyshade Advance V reference. An in silico study applied nested, participant-level cross-validation to evaluate Random Forest and Convolutional Neural Network (CNN) models for color correction, alongside uncertainty flags for identifying unreliable predictions. Results: The DSLR showed the lowest median ΔEab* in the laboratory (0.52) and clinical (0.68) phases. Clinically, 100% of Pixel, 99% of iPhone and 83% of Samsung measurements were within the selected ΔEab* ≤ 2.7 benchmark. Random Forest correction did not significantly reduce median error relative to calibrated photographs. The exploratory CNN introduced large smartphone errors, reaching ΔEab* = 7.89. Uncertainty flags detected 11/13 iPhone errors above 2.7 (84.6%; exact 95% CI 54.6–98.1%) and 18/23 Samsung errors (78.3%; 56.3–92.5%), while withholding 22% and 24% of predictions and leaving two and five errors undetected. Flagging did not establish added value over the calibrated photographic baseline. Conclusions: Under the tested conditions, the gray-card-calibrated DSLR workflow most closely agreed with the reference spectrophotometer. Smartphone performance varied by device and acquisition workflow. Random Forest correction provided no demonstrated added benefit, whereas the exploratory CNN introduced large errors in some smartphone predictions. Independent external validation is needed before AI-based correction or uncertainty flags can support clinical decisions.
No takes yet. Share an insight, caveat, or question.
Alkhodary et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: