Answers are grounded in this paper and cite their sources.
Background/Aims Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy (SAA) remains technically challenging, particularly for identifying the correct intestinal route. We developed carbon dioxide digital subtraction enterography (CDDSE), which combines CO₂ insufflation and digital subtraction imaging (DSI). This study aimed to evaluate the feasibility and procedural impact of CDDSE during balloon-assisted ERCP (BA-ERCP). Methods This retrospective feasibility study included 22 consecutive patients with SAA who underwent BA-ERCP procedures. The patients were divided into a non-CDDSE group ( n =12) and a CDDSE group ( n =10). The primary outcome was total radiation dose. Secondary outcomes included procedure time, target-site reach rate, route visualization success, and adverse events. Results The median total radiation dose was 51.0 mGy in the non-CDDSE group and 35.5 mGy in the CDDSE group ( p =0.410). In the CDDSE group, the median DSI-related dose was 2.7 mGy (6.8% of the total dose). Median procedure time was 60.0 and 51.0 minutes, respectively ( p =0.465). Target-site reach was achieved in 83.3% and 90.0%, respectively ( p =1.000). Route visualization using CDDSE was successful in all cases (100%). No procedure-related adverse events occurred. Conclusions CDDSE was feasible during BA-ERCP in patients with SAA and enabled consistent route visualization without a clear increase in procedure time or radiation exposure.
No takes yet. Share an insight, caveat, or question.
Maruyama et al. (2026) studied this question.