Answers are grounded in this paper and cite their sources.
Light fidelity (Li-Fi) sends data using LED room lighting. Designing a room link means choosing the light path and the LED layout; this paper studies both for a 5 × 5 × 3 m room. Line-of-sight (LOS), single-LED non-line-of-sight (NLOS), and dual-LED NLOS links are simulated in OptiSystem at 1, 3, and 4 m. The LOS link has the most stable Q-factor (18.86 to 17.01), the dual-LED NLOS link the lowest (17.84 to 15.85), and the single-LED NLOS link varies most with distance. A Lambertian channel model compares one LED with four sharing 1 W. With a 60° receiver field of view, four LEDs raise floor coverage at the forward-error-correction limit from 83.1 % to 100 % and cut the signal-to-noise-ratio spread from about 68 to 26 dB. With a 25° field of view, coverage is only 12.9 % (one LED) and 51.6 % (four LEDs). Four LEDs cover the whole floor with fields of view of 40° or more and 0.35 W; one LED reaches only 98.1 % even at 5 W. A reliable link should use LOS, several LEDs, and a wide-view receiver.
No takes yet. Share an insight, caveat, or question.
Narayan et al. (2026) studied this question.