Answers are grounded in this paper and cite their sources.
The widespread installation of externally attached elevators in existing multi-story buildings, driven by the need to improve vertical accessibility for residents, presents an unintended yet valuable research opportunity for structural dynamics. The structural interaction between the addition elevators and the main building possesses exploitable potential. Through rational parameter design, it is possible to simultaneously achieve effective regulation of seismic response while ensuring vertical transportation capacity, thereby realizing synergistic optimization of functionality and seismic performance. However, current engineering practice lacks simplified analytical tools for rapid seismic assessment of such coupled systems, and the influence of key design parameters remains insufficiently quantified. To address these gaps, a two-degree-of-freedom (2DOF) horizontal coupled vibration model of the main structure-elevator system is established, and the closed-form analytical solutions for its steady-state displacement and acceleration responses under mass-proportional harmonic excitation is derived. Parametric analysis over the full practical ranges of stiffness ratio and mass ratio identifies distinct optimal and unfavorable design intervals. The analytical solutions are validated against refined three-dimensional finite element simulations under multiple ground motions. Furthermore, a systematic seismic performance comparison is conducted between the two mainstream access configurations: half-level and same-level schemes. Results demonstrate that with appropriate parameter selection, the external elevator system can reduce the maximum horizontal displacement of the main structure, while simultaneously suppressing acceleration responses and inter-story drift. The half-level access scheme exhibits superior overall seismic performance due to its more favorable stiffness distribution and load-transfer path. The proposed 2DOF model, while limited to regular five-to six-story buildings during preliminary design, provides a computationally efficient tool for rapid scheme comparison and parametric optimization. This work offers both theoretical support for Chinese large-scale elevator retrofitting practice and a generalizable analytical framework for coupled primary-auxiliary structural systems worldwide.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: