Answers are grounded in this paper and cite their sources.
Objective To compare glass carbomer with composite resin, compomer, bulk-fill composite, and conventional glass ionomer cement (GIC) in terms of shear bond strength, microleakage, surface microhardness, and surface roughness. Materials and Methods Five restorative materials were tested, with 20 specimens per material for each outcome. Shear bond strength was measured on sound human third-molar dentin using a universal testing machine, and failure modes were assessed stereomicroscopically. Microleakage was evaluated in standardized Class V restorations after 1,000 thermal cycles using 0.5% basic fuchsin and an ordinal 0–3 scoring system. Surface microhardness was measured with the Vickers method, and surface roughness was assessed by atomic force microscopy. The original continuous outcomes were analyzed with Kruskal–Wallis, Mann–Whitney U, and Wilcoxon tests as appropriate. Preserved microleakage-score and failure-mode frequency data were reanalyzed using Kruskal–Wallis/Dunn and Fisher–Freeman–Halton exact tests, respectively, with Holm adjustment for pairwise comparisons. Results Glass carbomer had a mean shear bond strength of 2.4 ± 1.3 MPa, compared with 0.5 ± 0.9 MPa for conventional GIC and 5.6–5.8 MPa for the resin-based materials; in the original unadjusted pairwise analysis, glass carbomer occupied an intermediate position. Adhesive failure was common in the glass carbomer (85%) and GIC (95%) groups, and their failure-mode distributions differed significantly from those of the resin-based materials after multiplicity adjustment. Microleakage was observed in 85% of glass-carbomer and 95% of GIC restorations versus 40–45% of resin-based restorations. Mean top-surface microhardness followed the descriptive order composite > compomer > bulk-fill composite > glass carbomer > GIC; pairwise significance was based on the archived unadjusted analysis. The archived analysis also showed higher surface roughness for compomer and conventional GIC, while glass carbomer had a comparatively low Ra value, close to those of composite and bulk-fill composite. Conclusions Glass carbomer showed a distinct laboratory performance profile. Under the tested protocols, its mean bond-strength value was higher than that of conventional GIC, whereas the numerical reduction in microleakage was not statistically significant after adjustment for multiple comparisons. Relative to the resin-based materials, glass carbomer showed lower bond-strength and top-surface microhardness values and an intermediate microleakage pattern. Its polished surface roughness was comparatively low and similar in magnitude to composite and bulk-fill composite. Overall, the material’s ion-releasing and mineralization-related potential should be considered separately from its mechanical and interfacial performance.
No takes yet. Share an insight, caveat, or question.
Cantekin et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: