Answers are grounded in this paper and cite their sources.
An experimental and numerical investigation was conducted on a beam-to-beam self-centring connection incorporating superelastic shape memory alloy (SMA) plates and steel disc springs, hereafter termed the SMA-plate connection (SPC). The cyclic behaviour of a gap-minimised SPC specimen was characterised experimentally and compared with previously published results for a different gapped configuration (SPC-G). The gap-minimised specimen exhibited a flag-shaped hysteretic response, small residual deformation, and moderate energy dissipation. By contrast, SPC-G exhibited a low-stiffness stage during early loading and final unloading. This stage increased the deformation required to engage the principal resisting mechanism and lowered the initial stiffness. However, the self-centring response was not markedly degraded. A refined three-dimensional finite element (FE) model was developed. Its accuracy was assessed by comparing its predictions with the connection-level test results. Additional FE parametric analyses were conducted to further investigate the influence of the initial connection gap on the connection response. The results showed that increasing the initial gap extended the reduced-stiffness stage and slightly decreased the ultimate moment capacity. A computationally efficient connector-beam-truss model was then established to reproduce the principal hysteretic features and the gap-closing mechanism. The simplified model was used to analyse three-storey prototype self-centring steel frames with and without connection gaps under 30 mainshock-aftershock sequences. For the prototype frame with the adopted uniform connection gap, the analyses indicated higher maximum interstorey drift (MID) responses than those of the frame without gaps. The additional MID amplification associated with aftershocks was nevertheless smaller in the gapped frame. However, these differences are descriptive, as no statistical significance tests were performed. Residual drifts remained small and comparable for both frames. No consistent increase in residual drift was observed under the mainshock–aftershock sequences. For the analysed prototype and selected ground-motion sequences, the adopted connection gaps had only a limited influence on the system-level residual-drift response.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: