Answers are grounded in this paper and cite their sources.
Lighting design and regulation evaluate luminous flux with the CIE 2° standard photometric observer, V ( λ ), which weights short wavelengths less than the CIE 10° supplementary photometric observer, V 10 ( λ ). This study compares only these two CIE observers and quantifies how the choice between them changes the calculated energy demand of indoor LED lighting. For 979 phosphor-converted LED spectra (2700–6500 K), the luminous flux calculated with V ( λ ) was lower than that calculated with V 10 ( λ ) for every spectrum, by 5.30 % (2700 K) to 9.44 % (6500 K). Because illuminance is proportional to luminous flux, this difference carries over unchanged to installation level. For three EN 12464-1-compliant interiors with 4000 K and 6500 K luminaires, the energy difference was calculated as the reduction in installed luminous flux that still meets the illuminance target, assuming that the reduction is achieved by using fewer luminaires or, alternatively, by dimming. If the numerical targets are kept and only checked with V 10 ( λ ) (gross scenario), the full difference applies, allowing fewer luminaires in most installations. If the targets are first converted to V 10 ( λ ) using the incandescent and fluorescent sources under which they were established (net scenario), the difference falls to 1.1–4.4 %, achievable only by dimming.
No takes yet. Share an insight, caveat, or question.
Fryc et al. (2026) studied this question.