Answers are grounded in this paper and cite their sources.
Timely and accurate diagnosis of mechanical faults is crucial for the reliable operation of power transformers. This paper proposes a vibration–acoustic fault diagnosis framework based on improved Gramian angular field encoding and a multimodal fusion broad learning system (IGAF-MFBLS). First, amplitude-aware weighting and Hilbert instantaneous-phase similarity are incorporated into Gramian angular summation and Gramian angular difference fields, respectively, to construct modality-specific representations. Next, a shared-projection bidirectional cross-attention module with value-space residual connections and symmetric averaging (SPRA-BCA) is developed for multimodal fusion. Sharing the corresponding query, key, and value projection matrices across modalities reduces fusion parameters, while bidirectional attention captures cross-modal dependencies. Value-space residual connections retain each modality’s projected value features, and parameter-free symmetric averaging combines the two directional outputs. Finally, inverted dropout is applied to the BLS enhancement layer to improve generalization. The proposed framework achieves an average accuracy of 99.57% ± 0.13% on the laboratory dataset. It uses 0.148 M parameters and 9.821 MFLOPs, with an end-to-end inference latency of 0.32 s. These results support its effectiveness and computational efficiency for transformer mechanical fault diagnosis.
No takes yet. Share an insight, caveat, or question.
Xie et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: