Answers are grounded in this paper and cite their sources.
Deep intrusion detectors are usually compared by accuracy or F1-score at an ad hoc threshold, yet in operation the binding constraint is the false-alarm rate, and the value of an alert depends on how rare attacks are. We give threshold rules for any score-based detector whose guarantees are stated in these operational terms. Building on Neyman–Pearson umbrella classification, we derive the exact law of the false-positive rate (FPR) of order-statistic thresholds, its exact mean and hence the recall given up for the guarantee, and the calibration size needed for a given margin. From this law we construct joint FPR and recall certificates, precision guarantees as a function of prevalence, a selection rule under a budget on the total number of alerts, family-specific thresholds, and an anytime-valid monitor that detects calibration drift from reviewed or unlabeled alerts. On UNSW-NB15, CIC-IDS2017 and TON_IoT the certified rule violated the target FPR in 1.0% to 6.8% of draws, against 31% to 54% for the empirical quantile. At 1% prevalence it reached a precision of 0.50, against 0.034 for the default threshold. After a shift that raised the false-alarm rate several-fold, the monitor alarmed within a median of two windows, and recalibration restored the target.
No takes yet. Share an insight, caveat, or question.
Muteb Alshammari (2026) studied this question.