Answers are grounded in this paper and cite their sources.
Somatostatin receptor subtype 2 (SSTR2) antagonists are promising for tumor PET/CT, but reducing liver and kidney uptake without compromising tumor targeting and enabling scalable fluorine-18 radiotracer production remain important goals. We developed [18F]AlF-NOTA-Asp2-PEG2-JR11 and evaluated its preclinical properties and first-in-human PET/CT performance. Automated radiosynthesis required approximately 40 min and achieved >98% radiochemical purity. Compared with [18F]AlF-NOTA-JR11, the modified tracer showed higher AR42J cellular uptake and greater xenograft tumor uptake through 120 min. Competitive blocking reduced xenograft uptake by >90%, supporting SSTR2-specific targeting. In 10 participants, no adverse events were observed; imaging showed predominantly renal clearance and an effective dose of 0.0137 ± 0.0017 mSv/MBq. Uptake in 29 lesions from six participants was sustained between 60 and 120 min. Paired [18F]FDG imaging revealed heterogeneous uptake patterns, whereas available biopsies suggested qualitative PET-SSTR2 concordance. These findings support further clinical evaluation of this SSTR2-targeted tracer.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: