Answers are grounded in this paper and cite their sources.
Addressing the bottlenecks of separated concentration and defluorination units, high energy consumption, and low mass-transfer efficiency in wet-process phosphoric acid (WPA) refining, a novel integrated process for air-stripping concentration and defluorination in a turbulent ball contactor (TBC) is proposed within the thermodynamic framework of closed-loop tail-gas recycling in the process industry. The circulating gas simultaneously acts as a mass-transfer carrier, a heat-transfer carrier, and a medium for gas–liquid interfacial renewal and process intensification, thereby creating a triple “carrier–interface–intensification” effect. Theoretical analysis indicates that, under excess SiO2, the thermal decomposition of fluorosilicic acid and the reaction of HF with SiO2 can directionally generate highly volatile SiF4, thus achieving synchronous fluoride stripping and suppressing the formation of metal–fluoride complexes. In an industrial demonstration unit of Φ0.62 m × 9 m, three layers of lightweight hollow polypropylene spheres with a total static bed height of 1.5 m were used to treat hemihydrate wet-process crude phosphoric acid containing approximately 40 wt% P2O5 and >1.15 wt% F at atmospheric pressure. The results show that the suitable superficial gas velocity is 1.7–3.5 m/s, the liquid spray density is 49~99 m3/(m2·h), and the phosphoric acid throughput is 11–23 t/d (P2O5). The product contains >58 wt% P2O5 and <0.1 wt% F; the P2O5/F mass ratio increases from approximately 35 to above 726, the defluorination efficiency reaches 92–94%, and the steam consumption is reduced by 15.1% compared with the vacuum stripping defluorination process. Fluidization and mass-transfer analyses reveal that bed expansion and pressure drop are synergistically controlled by the gas-phase Reynolds number ReG and the liquid-phase Reynolds number ReL. The gas-phase overall height of a transfer unit (HTU) is 0.9–1.6 m and decreases significantly with increasing liquid-to-gas volume ratio. An empirical correlation is established as HTU = 673.98 × ReG−0.345 × ReL−0.353, with R2 = 0.7301, RMSE = 0.0807 m, and relative deviations between calculated and experimental values within ±15%. In addition, Sh = 9.95 × 10−8 × ReG1.5753 × ReL0.2489 × Sc1/3, with R2 = 0.9922, an average relative error of 2.89%, and a maximum relative error of 5.95%. This process enables simultaneous phosphoric acid concentration and deep defluorination in a single column, providing new principles, new methods, and fundamental scale-up data for green refining of WPA.
No takes yet. Share an insight, caveat, or question.
Li Ji (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: