Water ingestion can adversely affect compressor operation and degrade aero-engine performance. The water film formed inside the compressor after water ingestion may further intensify this effect. To investigate the influence of water-film adhesion on compressor performance, the transonic compressor stage NASA Stage 35 is selected as the test case. Based on existing water-film models for rotor blades, corresponding models are further developed for stator blade and casing surfaces. The predicted water-film thickness is converted into equivalent surface roughness, and numerical simulations are conducted under various water-ingestion conditions, with and without water-film adhesion. The results show that water films are distributed non-uniformly inside the compressor, mainly on the pressure sides of the rotor and stator blades and in the casing region near the rotor. When water-film adhesion is considered, aerodynamic losses increase and the tip leakage mass flow rate decreases. Consequently, the compressor characteristics shift toward the lower-performance side. At water-ingestion rates of 1%, 3% and 5%, the maximum reduction in isentropic efficiency reaches 1.09%, 1.76% and 2.38%, respectively, while the actual specific compression work increases by up to 17.6 J/kg, 145.6 J/kg and 160.6 J/kg. These results indicate that water-film adhesion acts as an additional localized loss mechanism and should be considered in the aerodynamic evaluation of compressors operating in wet environments.