Answers are grounded in this paper and cite their sources.
As part of the DreamFAB research project, this study investigates three demountable shear connectors for prefabricated steel-concrete composite beams, developed to enable non-destructive disassembly and reuse. The three configurations differ in the mechanism adopted to seat the connection against the steel flange. In the first two, the seating is provided by the head of a countersunk bolt housed in a countersunk hole in the flange, whereas in the third a conical end is machined on the body of the connector itself. Eighteen push-out tests were performed on solid slabs, including reference specimens with welded headed studs, and were evaluated in terms of shear resistance, load-slip response, stiffness, ductility, failure modes, behaviour over the load cycles and short-term demountability. All demountable connectors satisfied the 6 mm ductility criterion of EN 1994-1-1. The connector with the machined conical end reached an average shear resistance slightly above that of the welded studs and more than twice their characteristic slip capacity, with its stiffness being 45.30% lower. The comparability with welded headed studs is therefore established for shear resistance alone and does not extend to stiffness. Seating the head of the bolt in the flange proved ineffective, the countersunk variants being less stiff than the equivalent hexagon head ones, which indicates that the conical seating has to be implemented on the body of the connector and not on an intermediate element. Three-dimensional finite element models were developed and calibrated against the experimental results, reproducing the maximum load, the slip capacity and the failure mechanisms. A parametric study then supported a preliminary resistance formulation for the machined conical connector, processed within the EN 1990 reliability framework. No full-scale composite beam tests were performed, beam-level structural performance and automated assembly and disassembly feasibility being assessed in the next phase of the project. At connector level, the results indicate that a conical seating machined on the connector is a promising route to reusable composite construction, although beam-level, fatigue and long-term serviceability studies are required before general design implementation.
No takes yet. Share an insight, caveat, or question.
Gomes et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: