Answers are grounded in this paper and cite their sources.
PURPOSE: To compare the real-world outcomes of a novel navigated panretinal photocoagulation (PRP) laser system with a modified wavelength of 577 nm and variable pulse duration with conventional argon laser PRP in retinal vasoproliferative disease. METHODS: Retrospective single-center cohort study of eyes treated with PRP for proliferative diabetic retinopathy (DR), central retinal vein occlusion (CRVO) or other ischemic retinopathies. Argon laser PRP (2017-2020; argon laser cohort, ALC17/20) was compared with a navigated PRP laser system used at short pulse durations in two periods (navigated laser cohorts 2018-2020, NLC18/20, and 2022-2024, NLC22/24, after an in-house protocol change). The primary endpoint was retreatment-free survival; secondary endpoints were vitrectomy-free survival and laser parameters. Cox models were adjusted for age, indication, baseline disease severity and prior anti-VEGF treatment, with robust variance accounting for the inclusion of both eyes. RESULTS: A total of 497 eyes of 375 patients were included (ALC17/20: 160, NLC18/20: 206 and NLC22/24: 131 eyes). Compared to ALC17/20, navigated PRP used more pulses (median 1,542 in NLC18/20 and 2,043 in NLC22/24 vs 867 in ALC17/20), shorter pulses (30.0 ms in NLC18/20 and 23.8 ms in NLC22/24 vs 135.9 ms in ALC17/20) and less total energy (13,572 mJ in NLC18/20 and 15,645 mJ in NLC22/24 vs 28,403 mJ in ALC17/20, all p < 0.001). Two-year retreatment-free survival was 72.2% in ALC17/20, 62.0% in NLC18/20 and 42.7% in NLC22/24. After adjustment for age, indication, baseline disease severity and prior anti-VEGF treatment, the risk of retreatment was not significantly increased in NLC18/20 (HR 1.37, 95% CI 0.91-2.05) compared to the ALC17/20 group, but remained increased in NLC22/24 (HR 2.38, 1.59-3.56), indicating a worse clinical outcome in this cohort; this finding was robust in landmark, time-split and weighted analyses. Vitrectomy rates did not differ (adjusted HR 1.28 in NLC18/20 and 1.16 in NLC22/24). Neovascularization of the disc or elsewhere, younger age and worse visual acuity were independently associated with retreatment rates, whereas pulse duration, total energy and number of sessions showed non-significant trends only. CONCLUSIONS: Navigated PRP required more secondary interventions than argon laser PRP, partly because eyes with more active disease were more often selected for the new system; even after accounting for this, more retreatments were needed, indicating insufficient initial treatment. Vitrectomy rates did not differ. New laser systems should be accompanied by systematic evaluation of their efficacy and patient selection, and treatment protocols adapted accordingly.
No takes yet. Share an insight, caveat, or question.
Fleischer et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: