Answers are grounded in this paper and cite their sources.
Third paper in an open, pre-registered D-T reactor series (doi:10.5281/zenodo.24486255, doi:10.5281/zenodo.24488146). A random search of 4,973 tokamak designs (D2243) with H-mode access judged as in EU-DEMO (f_LH = P_sep/P_LH) found the best design 3.2x short, and corrected earlier H-mode passes that used a more forgiving power figure. A negative-triangularity (NT) mode was then added, assuming NT keeps H98 ~ 1 at reactor scale without an H-mode transition (DIII-D/TCV evidence, extrapolated), and the reactor search was redone in one locked pass (D2244). As locked, two HTS high-field designs (R 7 m, B 9 T: 559 MW net; R 8 m, B 8 T: 542 MW net) passed every limit, but an independent referee found they radiate 93-99% of their heating from the core. With a disclosed post-results cap on core radiated fraction (0.6, from the NT literature) and a positive-net-power requirement, no design passes: every net-positive burning design radiates at least 83% of its heating in the core (H98 = 1.0 samples). The next item is verifying the core radiation budget (synchrotron, profiles). All results are 0-D ESTIMATES. The zip contains the full process record: locks with SHA-256 fingerprints, deviation files (including one written after results were seen, disclosed), code, result files, research notes and the referee ledger entries (R111, R112). Written with AI assistance (Claude, Anthropic); responsibility for content rests with the author.
No takes yet. Share an insight, caveat, or question.
Danny Eldridge (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: