Answers are grounded in this paper and cite their sources.
Improving the energy efficiency of hydraulic drives requires consideration not only of steady-state volumetric, mechanical, and hydraulic losses, but also of additional energy dissipation caused by the dynamics of units under transient operating conditions. The aim of this study is to develop a mathematical model of total power losses in a hydraulic drive that accounts for unsteady pressure and flow rate, working-fluid compressibility, inertia of moving masses, temperature-induced viscosity variation, internal leakage, and mechanical friction. The object of the study is a rotary hydraulic drive comprising a fixed-displacement axial-piston pump, a 4/3 electrohydraulic directional control valve, and a variable-displacement reversible bent-axis axial-piston hydraulic motor. The proposed model is based on the instantaneous balance of mechanical and hydraulic power and accounts for temporary energy storage in inertial masses and elastically compressible fluid volumes. Total dissipative losses are represented as the sum of volumetric and mechanical losses in the pump and hydraulic motor, throttling losses in the directional valve, bypass losses in the relief valve, and losses in hydraulic lines, filters, and the cooler. The numerical implementation was performed for a pump with a displacement of 100 cm³/rev at a rotational speed of 1 000 rpm and a hydraulic motor with a maximum displacement of 250 cm³/rev at a nominal pressure of 30 MPa. It was established that, at a pump flow rate of about 100 L/min, the lower limit of predominantly displacement-based control is approximately 400 rpm. In the range of 500–1 000 rpm, the calculated overall efficiency is 75.72–76.95%, while total power losses are 12.15–12.80 kW. When the speed is reduced to 100 rpm, the maximum hydraulic-motor displacement is insufficient to absorb the pump flow; consequently, 67.73 L/min is bypassed through the relief valve, total losses increase to 44.50 kW, and efficiency decreases to 17.97%. Simulation of the transient cycle 100 → 500 → 1 000 → 500 → 100 rpm showed that the inertia of moving masses, the dynamics of hydraulic-motor displacement variation, and spool motion produce a short-term mismatch between pressure and flow rate and corresponding loss peaks. The results can be used to select hydraulic-unit parameters and to develop energy-efficient control algorithms for hydraulic drives of mobile technological machines.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2026) studied this question.
Synapse has enriched 9 related papers. Consider them for comparative context: