During reflow soldering, the spatial temperature distribution over a printed circuit board cannot be determined directly from a small number of measurement points; therefore, a reconstruction method is required. This study investigates a resistor-network reconstruction method based on the discrete Laplace equation and its acceleration using an influence matrix. The input data comprised seven K-type thermocouple readings at one selected instant from a single PCB (approximately 10 × 15 cm), represented by a 10 × 15 cell grid. The baseline method reconstructed the complete field using Jacobi iteration, whereas the accelerated method used a linear combination of precomputed unit-excitation basis fields. Validation included sensor-wise leave-one-out tests at internal measurement points, comparison with inverse distance weighting, and tests on rectangular and concave domains. For the available measurement state, the resistor-network method achieved a mean absolute validation error of 1.39 °C, while the online influence-matrix evaluation was approximately 54 times faster than the baseline method. The results indicate that, for fixed geometry and sensor layout, the method may support fast, repeated spatial reconstruction.