Answers are grounded in this paper and cite their sources.
Storage experiments count survivors. Beam experiments record trapped decay protons or compare beta tracks with neutron captures. Treating the decay, delayed record formation, and the apparatus state carried into subsequent measurements as parts of one physical history, we derive a common-rate criterion for the time-resolved beam records and the population yield ratio at scheduled storage holds. The model predicts the sign of the proton lifetime change under spectral reweighting and a reversal of the single-shell storage bias as the initial orbit mixture crosses equilibrium. The numerical results below belong to distinct model and evidence classes rather than to one additive correction or one nested confidence sequence. A nominal runwise proton-return envelope reaches 3.9923 s but reverses the measured backscatter slope. Enforcing a normalized slope of at least 0.48 gives 2.1253 s for two return laws, and simultaneous compatibility with all thirteen Gaussian series means gives 2.0591 s at nominal inputs. A fixed-axis input-box sensitivity gives a larger conditional bound of 3.177 s. Broader storage-preparation classes, evaluated over 875--890 s, give combined proton--bottle upper shifts of 4.2130 s for equilibrium low-energy orbits and 6.5824 s for arbitrary mixtures after the declared 50-s clean. These are alternative model classes and sensitivity bounds, not additive corrections. All remain below the 9.87-s proton--bottle central difference. Three storage readout and preparation models fit the four published timing means but predict lifetime shifts of opposite signs, so individual short holds provide a direct discriminator. For the electron experiment we use an algebraic pressure--chopper mixed contrast, not a randomized causal interaction. The retrospective fourth-cell residual of 6.1737 s corresponds to a log-contrast residual of \(0.007002\), which is \(0.63\) of the independent-cell statistical standard error. Under fixed nominal corrections, contact with the four centres requires a joint cellwise calibration pattern with an absolute \(L_∞\) radius of 0.113 percentage points; this is not a measured change of any one efficiency. An exact conditional count test is proposed for a new run. We therefore formulate a cross-apparatus reference criterion: one constant beta-decay hazard, together with independently fixed response models, must generate the proton record process, the electron-to-capture record law, and the storage survivor ratios. Population compatibility, calibration-induced nonidentifiability, and finite-data rejection are kept logically distinct. The criterion selects no published central value in advance.
No takes yet. Share an insight, caveat, or question.
Dohyeong Lee (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: