Answers are grounded in this paper and cite their sources.
Background/Objectives: Nasal intermittent positive pressure ventilation (NIPPV) is increasingly used in neonatal practice as an alternative to continuous positive airway pressure (CPAP) for respiratory support. Although its use has expanded across a range of clinical settings, the scope and strength of evidence supporting NIPPV remain incompletely defined. This scoping review aimed to map the current evidence for NIPPV in neonates, summarize reported clinical outcomes, and identify knowledge gaps to guide future research. Methods: A scoping review was conducted in accordance with PRISMA-ScR methodology. Electronic databases and clinical trial registries were searched from inception to September 2026 for studies evaluating NIPPV in neonatal populations. Evidence was charted separately for (a) primary respiratory support, (b) post-extubation prophylaxis, and (c) other settings. Systematic reviews and meta-analyses were prioritized, supplemented by randomized controlled trials (RCTs) and observational studies where necessary. This review did not conduct a new meta-analysis or independent GRADE assessment. Results: Twenty relevant studies were identified, including seven systematic reviews/meta-analyses, one network meta-analysis, two RCTs, six observational studies, four review articles, and one case series. As Primary support compared with CPAP, NIPPV reduced respiratory failure (low to very low Certainty of evidence (CoE)) and need for invasive mechanical ventilation (low to very low CoE). As post-extubation support, NIPPV compared with CPAP reduced respiratory failure (moderate CoE) and need for reintubation (moderate CoE). Limited evidence around benefit of synchronization. Several studies also reported reductions in pulmonary air leaks, oxygen requirement, and duration of hospitalization (very low CoE). Very low certainty of evidence around reduction in bronchopulmonary dysplasia, with conflicting findings between meta-analyses and large cohort studies. No difference in mortality, necrotizing enterocolitis, severe intraventricular hemorrhage, retinopathy of prematurity, or sepsis. Evidence for rescue therapy after CPAP failure, delivery room stabilization, neonatal surgery, and peri-intubation support was limited, inconsistent, and sparse; no published research on NIPPV during neonatal transport. Conclusions: Available evidence suggests that NIPPV may improve short-term respiratory outcomes in specific neonatal settings, particularly primary and post-extubation support. Interpretation is limited by heterogeneity in devices, synchronization, interfaces, mean airway pressure, comparators, populations, timing, and outcome definitions. This review maps the evidence and does not establish comparative effectiveness or clinical recommendations. Important evidence gaps remain regarding long-term outcomes, extremely preterm infants, neonatal transport, delivery room use, and emerging synchronized and neurally adjusted NIPPV technologies.
No takes yet. Share an insight, caveat, or question.
Panchal et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: