Answers are grounded in this paper and cite their sources.
This study presents a comprehensive numerical investigation of a novel advanced bi-layered PCM enhanced Trombe wall (A-biPCMTW) design for improving passive thermal stability in buildings. The research addresses critical limitations of conventional Trombe walls, specifically overheating and reverse heat loss, through multi-objective optimization of PCM layer configurations with complementary melting temperatures. Comparative analysis across heating and cooling seasons reveals that the A-biPCMTW configuration substantially outperforms conventional Trombe walls (TW) and insulated variants (TWI). The results demonstrate annual heating load reductions of 8.33% relative to the bi-layered PCM configuration (biPCMTW) and 19.2% compared to TWI, while achieving annual cooling load reductions of 48.9%, relative to TW. Thermal comfort metrics show marked improvements, with the A-biPCMTW reducing annual discomfort hours by 36.7% and integrated discomfort degree-hours by 38.1% compared to conventional walls. The system achieves a relative fluctuation coefficient of 0.412, representing a 10.8% reduction in indoor temperature fluctuations. From a thermodynamic perspective, the A-biPCMTW attains 44.32% energy efficiency gain and an exergy efficiency of 3.12% during winter months. Overall, the new configuration demonstrated significant advantages over conventional building envelopes in both cold and hot conditions.
No takes yet. Share an insight, caveat, or question.
Dimassi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: