Answers are grounded in this paper and cite their sources.
Introduction Apnea diving in warm tropical waters involves repeated exertion, pronounced autonomic responses, and intermittent hypoxia, creating challenges for continuous physiological monitoring in the field. Continuous glucose monitoring (CGM) can capture interstitial glucose dynamics under free-living conditions, but field deployment guidance for open-water apnea diving is sparse. Prolonged multi-hour apnea sessions may deplete carbohydrate stores and precipitate end-of-session hypoglycemia, which could compound hypoxic stress, motivating continuous field monitoring. Here, we report an implementation-focused protocol for CGM deployment during warm-water ocean apnea diving and outline practical considerations to support field use. Methods We describe an implementation-focused protocol for deploying CGM during routine warm-water, open-ocean apnea diving. Eighteen adult apnea divers (n=18) completed repeated apnea sessions with surface recovery. The objective was to evaluate operational feasibility across multi-dive sessions rather than interpret individual-dive glucose responses. The protocol focused on standardizing sensor placement, adhesion reinforcement, anchor-timestamp synchronization, structured logging, and prespecified feasibility criteria, with capillary finger-prick glucose obtained at rest for comparison. Results CGM devices were deployed across 560 dives spanning a wide range of real-world diving exposures. Eleven of 18 participant-sessions (61.1%) achieved first-attempt sensor retention and data export; the remaining seven (38.9%) required sensor replacement; all seven occurred before the diving day (six from adhesive detachment during showering or heavy sweating, one from failed sensor insertion), rather than from wetsuit transitions or in-water exposure. All 18 sessions ultimately yielded exportable, time-aligned data, though in-dive glucose measurements were not analyzed. Paired capillary measurements at rest showed strong linear correspondence with contemporaneous CGM readings. As the comparison used a small, non-independent sample obtained at rest during surface intervals, it is presented as an exploratory surface-rest functional check rather than formal validation of agreement. Conclusions CGM can be deployed during warm-water ocean apnea diving when sensor adhesion, scanning logistics, and time alignment are planned a priori. These findings demonstrate sensor retention and data availability under field conditions, not analytical accuracy during apnea, immersion, or pressure exposure, which this study did not evaluate. Standardized deployment and reporting practices may improve reproducibility and support multi-sensor physiological monitoring in apnea research, though not for real-time in-water decision-making.
No takes yet. Share an insight, caveat, or question.
Cervera et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: