Answers are grounded in this paper and cite their sources.
Trace halogen impurities in hydrogen fuel can significantly impair proton exchange membrane fuel cell (PEMFC) performance and durability. This study systematically investigates the effects of hydrogen halides (HCl, HBr, and HI) using rotating disk electrode measurements and single-cell testing. Electrochemical analyses showed strong halogen species adsorption on platinum, reducing electrochemical surface area (ECSA) and oxygen reduction reaction (ORR) activity. Poisoning severity followed the order HI > HBr > HCl, with iodide causing near-complete ORR inhibition and promoting a two-electron reaction pathway. Single-cell experiments with ppm-level halide concentrations revealed a strong dependence on operating conditions: performance losses were limited at high humidity but became significant and partly irreversible under low-humidity conditions. Halide contamination reduced both anode and cathode ECSA, indicating migration of halogen species through the membrane. Combined half-cell and single-cell results demonstrate that even trace hydrogen halides can adversely affect PEMFC performance, highlighting the need for stringent halogen impurity control.
No takes yet. Share an insight, caveat, or question.
Aarhaug et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: