Answers are grounded in this paper and cite their sources.
Archery requires sustained attention and precise movement timing. This study evaluated the EEG classification of the baseline, aiming-imagery, and release-imagery stages in a visually cued, fixed-order task. EEGs from 22 participants were recorded with a 16-channel portable system. For cross-subject analysis, Euclidean alignment preceded the extraction of nine approximate joint diagonalization common spatial pattern (AJD-CSP) features, 96 temporal features, and 48 band-power features, followed by feature fusion, selection, standardization, and SVM or ensemble classification. A shared configuration was selected by participant-grouped five-fold validation on calibration-pool data from the 22 participants, with reserved test trials excluded. Cross-subject evaluation achieved 72.08% accuracy with no target labels in the final fitting, and 76.39% and 78.29% with 10% and 50% labeled target calibration, respectively. Unlabeled target EEGs were used for transductive alignment. At 50% calibration, the accuracy was 74.41% without temporal features, 78.45% without frequency features, and 79.24% with Uniform sample weights. Replacing the band power with ERD/ERS yielded 77.62% at 50% calibration. In the first-split pooled confusion matrix, the baseline recall was 97.39%, and the accuracy among true aiming and release test samples was 68.75%. Temporal features provided the largest numerical gain among the evaluated feature blocks. Aiming-release confusion remained the principal error.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: