Why the study?
Although echo time values of 350 and 650 ms were suggested to provide favorable lymphatic visualization in non-contrast magnetic resonance lymphangiography for patients with congenital heart disease, statistical validation for clinical standardization was lacking.
Population
29 image sets from 16 patients with CHD at a specialized center in Japan
Comparison
Echo time 350 ms vs echo time 650 ms in NCMRL
Design
Single-center retrospective observational study
Answers are grounded in this paper and cite their sources.
May inform non-contrast MR lymphangiography protocols in congenital heart disease; leaves open prospective validation before clinical adoption.
Lymphatic complications can occur both before and after congenital heart disease (CHD) surgery, such as the Fontan procedure. Early detection and management of these lymphatic abnormalities are essential to improve perioperative outcomes. Non-contrast magnetic resonance lymphangiography (NCMRL) is a promising and widely applicable imaging technique. Previous work suggested that echo time (TE) values of 350 and 650 ms may provide favorable lymphatic visualization, but statistical validation for clinical standardization was lacking. This study aimed to evaluate the effects of TE 350 ms and 650 ms on lymphatic vessel visualization and to determine the clinical utility of TE selection for NCMRL. This retrospective observational study included 29 image sets from 16 patients with CHD who underwent NCMRL between August 2022 and November 2023 at a specialized center in Japan. Signal intensities (SI) and signal intensity ratios (SIR) of lymphatic vessels and surrounding tissues were quantified and compared. Anatomical evaluations focused on lymphatic structure delineation. Statistical comparisons between TE 350 ms and TE 650 ms were performed using a linear mixed-effects model and estimated marginal means. Sixteen patients (mean age, 23 ± 19 years; 8 men and 8 women) were evaluated. TE 350 ms produced significantly higher SI lymp (p = 0.0014) and SI bg (p = 0.0024) than TE 650 ms, while no significant difference was observed in SIR (p = 0.59). TE 350 ms also provided subjectively favorable anatomical visualization of the thoracic duct and lymphatic structures compared with TE 650 ms. These findings suggest that TE 350 ms may offer practical advantages for anatomical assessment of lymphatic vessels in patients with CHD, although the signal intensity ratio did not differ significantly between the two TE settings. Further studies with larger cohorts are warranted to determine the generalizability of these findings and to establish standardized NCMRL protocols.
No takes yet. Share an insight, caveat, or question.
Hondera et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: