Key result
BeFlared bridging stent grafts are linked to ~25-minute shorter fluoroscopy times during FEVAR.
Why the study?
Whether BeFlared bridging stent grafts reduce fluoroscopy and procedure times during Fenestrated Endovascular Aneurysm Repair compared to traditional bridging stent grafts was uncertain.
Does the use of BeFlared bridging stent grafts reduce fluoroscopy and procedure times during Fenestrated Endovascular Aneurysm Repair (FEVAR) compared to traditional bridging stent grafts?
Cohort (n=48)
Does the use of BeFlared bridging stent grafts reduce fluoroscopy and procedure times during Fenestrated Endovascular Aneurysm Repair (FEVAR) compared to traditional bridging stent grafts?
Using BeFlared bridging stent grafts during fenestrated endovascular aneurysm repair significantly reduces fluoroscopy time, procedure time, and radiation dose compared to traditional bridging stent grafts while maintaining comparable 30-day technical success and target vessel stability.
Answers are grounded in this paper and cite their sources.
BeFlared grafts were associated with shorter fluoroscopy time in FEVAR; retrospective data leaves open need for randomized confirmation before practice change.
OBJECTIVE: This study aimed to determine whether BeFlared bridging stent grafts (BSG) reduce fluoroscopy and procedure times during Fenestrated Endovascular Aneurysm Repair (FEVAR) compared to traditional BSGs. Secondary endpoints included radiation doses, contrast agent volumes, and 30-day outcomes. METHODS: A retrospective cohort of patients treated with FEVAR from 2021 to 2026 was analyzed. Patients receiving BeFlared BSG (2025-2026) were compared with those treated with traditional BSGs (2021-2025). Demographics and procedural parameters, including fluoroscopy and procedure times, radiation doses, and contrast volumes, were collected. Technical success and 30-day outcomes, including target vessel instability (TVI), were assessed through clinical visits and computed tomography angiography. RESULTS: A total of 48 patients with 177 target vessels (TVs) were included: 59 TVs treated with BeFlared BSG and 118 with Advanta/BeGraft. The BeFlared group had significantly shorter fluoroscopy time (54 (95% CI: 49-70) minutes vs. 79 (76-91) minutes; p < 0.01) and procedure time (169.5 minutes (153.5-187) vs. 208.5 minutes (196-247) ; p = 0.02). Significant differences were also noted in radiation dose (Air Kerma, 1500 (1191-1906) vs. 2448 (1725-2950) p = 0.01; DAP, 157.8 (131.3-192.8) vs. 260.7 (187.7-374.5) p = 0.04). Contrast volumes were similar (p = 0.5). Technical success was good in both groups (BeFlared 98.3% vs. Advanta/BeGraft 97.4%; p = 0.37); with TVI at 3% in the BeFlared group versus 2% in Advanta/BeGraft (p = 0.59). No stent-related endoleaks were observed. CONCLUSIONS: BeFlared BSG use in FEVAR led to reduced fluoroscopy and procedure times, along with lower radiation doses, while both graft types demonstrated excellent short-term outcomes.
No takes yet. Share an insight, caveat, or question.
Lindskog et al. (2026) conducted a cohort in Aortic aneurysm undergoing Fenestrated Endovascular Aneurysm Repair (FEVAR) (n=48). BeFlared bridging stent graft (BSG) vs. Traditional bridging stent grafts (Advanta/BeGraft) was evaluated on Fluoroscopy time and procedure time (p=<0.01). BeFlared bridging stent grafts reduced fluoroscopy time and procedure time compared to traditional stents during FEVAR.
Synapse has enriched 10 related papers. Consider them for comparative context: