Key result
Updated AAP CCHD screening algorithm linked to ~4-fold higher infant referrals than current CPS protocol.
Why the study?
The AAP recently recommended a more restrictive CCHD pulse oximetry screening algorithm, and because Ontario's baseline referral rates and performance exceed those in the US, the impact of adopting the updated AAP algorithm or an alternative modified CPS algorithm on referral volumes and healthcare utilization needed estimation.
Does the updated AAP or a modified CPS pulse oximetry screening algorithm improve CCHD detection without excessively increasing referral rates and healthcare resource utilization compared to the current CPS algorithm in newborns in Ontario?
Observational (n=820,905)
Yes
Does the updated AAP or a modified CPS pulse oximetry screening algorithm improve CCHD detection without excessively increasing referral rates and healthcare resource utilization compared to the current CPS algorithm in newborns in Ontario?
A modified CPS pulse oximetry screening algorithm using a single repeat screen offers a balanced alternative to the 2025 AAP algorithm by improving CCHD detection sensitivity to 85.9% while avoiding the 4-fold surge in referrals and healthcare utilization estimated with the full AAP update.
Answers are grounded in this paper and cite their sources.
May substantially increase referrals and utilization with the AAP update; leaves open whether single-repeat modifications optimize CCHD screening efficiency.
Background Pulse oximetry screening (POS) is a simple, non-invasive bedside tool to help detect hypoxic babies with Critical Congenital Heart Disease (CCHD). The CCHD POS algorithm used to interpret screens for Ontario babies was endorsed by the Canadian Paediatric Society (CPS), the American Academy of Pediatrics (AAP), and is used worldwide. In January 2025, the AAP recommended using a more restrictive algorithm based on two key changes to simplify the screen and improve performance. Published referral rates and screen performance for CCHD screening programs in the US are lower than for Ontario, despite using the same POS algorithm. Objectives To estimate the impact of the updated AAP CCHD POS algorithm on referral volumes and healthcare utilization for Ontario babies and compare the estimated impact of an alternative modification to the CPS algorithm (modified CPS algorithm), adopting only one of the two suggested algorithm changes. Design/Methods Infants born in Ontario from 2019 – 2024 who had CCHD POS were included. Routine data collected through administration and follow-up of CCHD screening included oxygen saturation measurements from the right hand and either foot, screen determinations, and definitive diagnoses of referred infants. Referral rates, sensitivity, specificity, and false positive rates were calculated using the current CPS algorithm and then compared to estimates modelled using the updated AAP and modified CPS (only one repeat screen versus two) algorithms. Rates of known and estimated healthcare resource utilization (ECHO, unit or hospital transfer) of referrals were also compared for each algorithm. Results There were 820,905 eligible CCHD screens. Sensitivity and specificity of the current CPS, updated AAP, and modified CPS algorithms were 83.6% and 99.9%, 86.3% and 99.6%, and 85.9% and 99.9%, respectively. Compared to current referral rates, babies were 4 times more likely to be referred in models using the updated AAP algorithm (RR 4.04; 95% CI: 3.78, 4.34), translating to a 4.3-fold increase in healthcare resource utilization. Using the modified CPS algorithm, babies were 1.3 times more likely to be referred (RR 1.31; 95%CI 1.24, 1.46). The false positive rate for the current CPS, updated AAP, and modified CPS algorithms was 0.1%, 0.45%, and 0.2%, respectively. Conclusion A modified version of the current CPS CCHD POS algorithm, using only a single repeat, is an alternative to the newly updated AAP algorithm that simplifies the screen and may expedite detection of babies with CCHD, while potentially minimizing false positives and significant increases in healthcare resource utilization in Ontario. This study can help to inform strategies for CCHD screening programs in Canada.
No takes yet. Share an insight, caveat, or question.
Milne et al. (2026) conducted an observational in Critical Congenital Heart Disease (CCHD) (n=820,905). Updated AAP and modified CPS CCHD pulse oximetry screening algorithms vs. Current CPS CCHD pulse oximetry screening algorithm was evaluated on Referral rates for CCHD screening (updated AAP vs current CPS algorithm) (RR 4.04, 95% CI 3.78-4.34). The updated AAP CCHD screening algorithm increased infant referrals 4-fold versus the current CPS algorithm, while a modified CPS algorithm increased referrals by 1.3-fold.
Synapse has enriched 10 related papers. Consider them for comparative context: