Key result
PASCAL M-TEER achieves ~2.7-fold higher odds of sustained MR <=1+ at 6 months vs MitraClip.
Why the study?
The CLASP IID trial established the safety and effectiveness of the PASCAL system for M-TEER in prohibitive-surgical-risk DMR patients, motivating detailed characterization of echocardiographic methods, outcomes, and baseline variables associated with residual MR ≤1+.
Does mitral transcatheter edge-to-edge repair with the PASCAL system improve the achievement and sustainability of residual mitral regurgitation ≤1+ compared to MitraClip in prohibitive surgical risk patients with significant symptomatic degenerative mitral regurgitation?
RCT (n=180)
Randomized
Does mitral transcatheter edge-to-edge repair with the PASCAL system improve the achievement and sustainability of residual mitral regurgitation ≤1+ compared to MitraClip in prohibitive surgical risk patients with significant symptomatic degenerative mitral regurgitation?
In patients with degenerative mitral regurgitation at prohibitive surgical risk, treatment with the PASCAL M-TEER system and having a smaller baseline flail gap were independently associated with significantly higher rates of sustained residual MR ≤1+ at 6 months compared to MitraClip.
Answers are grounded in this paper and cite their sources.
Supports TEER evaluation in prohibitive-risk degenerative MR; leaves open durability and clinical outcome confirmation in RCTs.
BACKGROUND The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial; NCT03706833) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).
No takes yet. Share an insight, caveat, or question.
Marcoff et al. (2023) conducted an RCT in Symptomatic degenerative mitral regurgitation (n=180). PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) vs. MitraClip was evaluated on Sustained residual mitral regurgitation (MR) <=1+ at 6 months (OR 2.72, 95% CI 1.08-6.89). PASCAL M-TEER achieved higher rates of sustained residual MR <=1+ at 6 months than MitraClip.