Key result
Novel Valsalva assistance system boosts PFO diagnostic accuracy by ~8 percentage points vs conventional VM.
Why the study?
The efficacy of right-heart contrast echocardiography for patent foramen ovale detection depends on a standardized Valsalva maneuver, motivating evaluation of a novel automated Valsalva maneuver assistance system against the conventional maneuver.
Does a novel automated Valsalva maneuver assistance system improve the diagnostic accuracy of right-heart contrast echocardiography for patent foramen ovale detection compared to the conventional Valsalva maneuver in patients with clinically suspected patent foramen ovale?
RCT (n=106)
Randomized crossover order
Does a novel automated Valsalva maneuver assistance system improve the diagnostic accuracy of right-heart contrast echocardiography for patent foramen ovale detection compared to the conventional Valsalva maneuver in patients with clinically suspected patent foramen ovale?
An automated Valsalva maneuver assistance system significantly improves diagnostic agreement with transesophageal echocardiography, enhances hemodynamic response, and reduces patient training time during right-heart contrast echocardiography for patent foramen ovale detection.
Answers are grounded in this paper and cite their sources.
Automated Valsalva assistance may enhance PFO detection on contrast echocardiography; leaves open whether it improves outcomes or warrants routine adoption.
Background: The efficacy of right-heart contrast echocardiography (RHCE) for patent foramen ovale (PFO) detection depends on a standardized Valsalva maneuver (VM). This study evaluated the diagnostic performance and operational efficiency of a novel automated VM assistance system compared with the conventional VM, using transesophageal echocardiography (TEE) as the reference standard. Methods: A total of 106 patients with clinically suspected PFO were prospectively enrolled between June and December 2023. All participants underwent RHCE using both the conventional VM and the novel assistance system in a randomized order. The assistance system automated airway pressure monitoring (target pressure, ≥40 mmHg), strain duration (5 s), and rapid release. Primary outcomes included diagnostic sensitivity, specificity, and agreement with TEE as assessed by Cohen’s kappa coefficient. Secondary outcomes included training time and hemodynamic efficacy (assessed by atrial septal bulging). Results: The system-assisted group demonstrated significantly higher diagnostic agreement with TEE (Cohen’s kappa =0.942) than the conventional group (Cohen’s kappa =0.789; P=0.026). In the system-assisted group, sensitivity, specificity, and accuracy were 100.0%, 95.7%, and 97.2%, respectively, compared with 91.9%, 88.4%, and 89.6%, respectively, in the conventional group. Further, the assistance system significantly reduced patient training time (7.9±0.9 vs. 19.6±5.7 s; P<0.001) and increased the height of atrial septal protrusion (9.6±2.3 vs. 8.3±2.2 mm; P<0.001). The assistance system also yielded significantly higher right-to-left shunt (RLS) grades (P=0.028). Conclusions: Compared with the conventional VM, the novel VM assistance system significantly reduced training time, enhanced the hemodynamic response, and improved the diagnostic accuracy of RHCE for PFO detection. By standardizing the provocation process and enabling real-time signal integration, the novel VM assistance system may provide a more reliable and efficient tool for clinical practice.
No takes yet. Share an insight, caveat, or question.
Ye et al. (2026) conducted an RCT in Patent foramen ovale (n=106). Automated Valsalva maneuver assistance system vs. Conventional Valsalva maneuver was evaluated on Diagnostic sensitivity, specificity, and agreement with transesophageal echocardiography (Cohen's kappa) (Cohen's kappa 0.942 vs 0.789, p=0.026). The novel Valsalva maneuver assistance system improved PFO diagnostic agreement with TEE compared with conventional VM.